Cavitron
®
Plus
Ultrasonic Scaler
Cavitron
®
Plus
Ultrasonic Scaler
Installation and Service Manual
Please read carefully and completely before operating unit.
Page view 0
1 2 3 4 5 6 ... 38 39

Summary of Contents

Page 1

Cavitron® Plus™Ultrasonic ScalerCavitron® Plus™Ultrasonic ScalerInstallation and Service ManualPlease read carefully and completely before operating u

Page 2

 9Power IndicatorLights (3 Sec. delay) when the Main Power ON/OFF Switch is ON (“I” position). Low Batte

Page 3 - 

 The many styles of Cavitron and Cavitron Bellissima 30K Ultrasonic Inserts are easily interch

Page 4 - 

Pressing anywhere on the top of the foot control activates the system. • 1.

Page 5 - 

For optimal access to both the upper and lower arches, the backrest of the chair should be adjusted as for other dental procedu

Page 6 - 

 1. Remove ultrasonic insert used. Clean and sterilize the ultrasonic insert(s) following the procedures outlined in th

Page 7 - 

2. Check that the system’s power cord plug is fully seated in an approved AC wall outlet. 3. Check that the wall outlet is functional.Sympt

Page 8 - 

The Cavitron Plus Ultrasonic Scaler is warranted for TWO YEARS from date of purchase. The Steri-Mate Handpiece enclosed w

Page 9 - 

.PURGEIlluminates when the Main Power On/Off switch is in the “ON” posi

Page 10

1. Check that the Main Power Switch is in the ON (I) position, and that the detachable power cord is fully seated in the receptacle o

Page 11 - 

™This troubleshooting section is meant for use by qualified Cavitron® Service Technicians.

Page 13 - 

™This troubleshooting section is meant for use by qualified Cavitron® Service Technicians.

Page 14 - 

™This troubleshooting section is meant for use by qualified Cavitron® Service Technicians.

Page 15

™This troubleshooting section is meant for use by qualified Cavitron® Service Technicians.

Page 16 - 

™This troubleshooting section is meant for use by qualified Cavitron® Service Technicians.

Page 17 - P

™This troubleshooting section is meant for use by qualified Cavitron® Service Technicians.

Page 18 - 

CAUTION: THIS UNIT CONTAINS COMPONENTS WHICH ARE SUBJECT TO ELECTROSTATIC DISCHARGE (ESD) DAMAGE. THE

Page 19 - 

8. Lift the protective cover from the Power Entry module. The fuses are mounted vertically under the cover. Use a small flat blade scr

Page 20 - 

10. Position the replacement Power Supply assembly with the RED-BLK wire connector at the rear. 11. Slide the Power Supply assembly under th

Page 21

 1. Follow the steps above in Section A for “Top Cover Removal”. 2. Unplug the Top Cover ribbon cable at

Page 22



Page 23

            3         3          3

Page 24



Page 25 - 



Page 26 - Water Regulator/Solenoid



Page 27



Page 28 - Molded Overlay

33

Page 29



Page 30 - 



Page 31 - 



Page 32



Page 33

Manufactured by:DENTSPLY ProfessionalDENTSPLY International1301 Smile WayYork, PA 17404-1785Distributed by:DENTSPLY CanadaWoodbridge, OntarioL4L 4A3U

Page 34

 Congratulations!Your decision to add the Cavitron® Plus™ Ultrasonic Scaler to your practice represents a wise investment in good dentistr

Page 35

All general supra and subgingival scaling applicationsPeriodontal debridement for all types of periodontal diseasesEn

Page 36

Like bristles of a toothbrush, ultrasonic insert tips “wear” with use. Inserts with just 2 mm of wear lose about 50% of their scaling efficienc

Page 37

Carefully unpack your Cavitron Plus System and verify that all components and accessories are included: 1. Cavitron® Plus™

Page 38

To remove the water line from the Cavitron Plus System, turn off the dental office water supply. Disconnect the water supply line from the dent

Page 39 - Worldwide Service Centers

Main Power ON/OFF Switch ON/OFF Switch located at the center front underside of the system. Ultrasonic Power Level ControlTurn knob to select the ult